Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection Of The Tubular Motor (Figure K ); Control With A 1-Pole Switch (Closer) (Figure L ) - RADEMACHER X-line Handbuch

Rohrmotoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection of the tubular motor (Figure k )

11
(a)
(b)
(c)

Control with a 1-pole switch (closer) (Figure l )

The X-line tubular motor can be controlled locally and independently of the KNX bus by
means of connecting a 1-pole switch (closer) to the "external switch" conductor.
In doing so, the switching sequence is as follows:
OPEN/STOP/CLOSE/STOP, and so on.
12
(a)
(b)
(c)
58
(d)
(e) (f) (g)
(h)
(i)
(d)
(e) (f) (g)
(h)
(i)
Legend
(a) =
set button (11)
(b/d) = socket box
(c) =
mains 230 V/50 Hz
Pin assignment
(e) =
PE
green / yellow
(f) =
N
blue
(g) =
L
black
(h) =
external switch white
(is not connected)
(i) =
not assigned
violet
(is not connected)
IMPORTANT
◆ If the "external switch" (h) lead is not used, then it must be connected to the
neutral conductor (f),(see fig. k).
◆ If the motor is connected in accordance with figure k, then it can only be controlled
via the KNX bus.
Legend
(a) =
set button (11)
(b) =
1-pole switch
(c) =
mains 230 V/50 Hz
(d) =
socket box
Pin assignment
(e) =
PE
green / yellow
(f) =
N
blue
(g) =
L
black
(h) =
external switch white *
(i) =
not assigned
violet
* maximum cable length between tubular motor and external switch = 10 m
IMPORTANT
◆ If the "external switch" (h) lead is not used, then it must be connected to the
neutral conductor (f), (see fig. k).
EN

Werbung

Kapitel

Inhaltsverzeichnis
loading