5.2 Positional requirements

WARNING
Crushing of hands
Death or serious personal injury
If the pump is to be installed in a position where it is
accessible, the coupling must be suitably isolated from
human touch. The pump can for instance be built into
a flow sleeve.
Depending on motor type, the pump can be installed either
vertically or horizontally. A complete list of motor types suitable for
horizontal installation is shown in section Motors suitable for
horizontal installation.
If the pump is installed horizontally, the outlet port must never fall
below the horizontal plane. See fig. Positional requirements.
Positional requirements
Pos.
Description
A
Allowed
B
Not allowed
If the pump is installed horizontally, e.g. in a tank, we recommend
that you fit it in a flow sleeve.
Related information
5.2.1 Motors suitable for horizontal installation
10
A
B
5.2.1 Motors suitable for horizontal installation
Output power
50 Hz
Motor
[kW]
MS
All
MMS6
5.5 - 37
MMS8000
22-92
MMS10000
75-170
MMS12000
147-190
CAUTION
Hot surface
Minor or moderate personal injury
If the pump is used for pumping hot liquids (40 to 60
°C), make sure that persons cannot come into contact
with the pump and the installation, e.g. by installing a
guard.
During operation, the suction interconnector of the pump
must always be completely submerged in the liquid. Make
sure that the NPSH values are fulfilled.

5.3 Pump/motor diameter

We recommend that you check the borehole with an inside calliper
to ensure unobstructed passage.