Equipements / Accessories / Ausrüstungen
J
S
EED CONTROLLER
The seed controller's main ECU, which is placed under the distribution head, is equipped with two status LEDs.
Red LED
LED status
Quick fl ashing
OFF
always on
Green LED
LED status
Slow fl ashing
OFF
always on
Red LED
LED status
OFF
always on
Quick fl ashing
Slow fl ashing
Green LED
LED status
Slow fl ashing
Quick fl ashing
OFF (with red LED OFF)
OFF (with red LED ON)
always on
The operation of the seed controller is only guaranteed with wheat.
Information
No communication with the fl ow sensors.
Normal operation
No CAN communication.
Information
Normal operation
No power supply voltage
Software updating
Information
Normal operation
Sensor dirty or obstructed.
No communication with the ECU
Sensor in confi guration or acquisition mode.
Information
Normal operation, without product passage.
Normal operation, with product passage detection.
No power supply voltage
Sensor dirty.
Software updating
Check
Check the connections.
Check the connections.
Check
Check that the machine is under voltage.
Check that the update was successful.
Check
Check if the sensor is obstructed
or dirty and clean it.
Check the connections.
Check
Check the connections.
Clean the blocking sensor No. X