Utilisation et Réglages de la machine / Machine use and Settings / Bedienung und
Einstellung der Maschine
M
S
(
EEDING CONTROLLER
OPTIONAL
The sowing controller allows continually monitoring whether the rows do deliver the seeds and are not clogged.
It is still possible that dosage levels, type of seed or other factors do not allow the sowing controller to operate.
When the seeding controller disengages, an alert is sent to the user, then an indicator
bar on the main screen.
In all cases, it is up to the user to check that the sowing controller is active and has a detection threshold
conditions before starting any sowing job.
To check this, simulate a forward movement speed from the simulation menu and in sowing mode, block a sowing component.
The sowing controller should alert you within 60 seconds.
If the seeding controller does not inform you fast enough, then increase the detection threshold
«Advanced Settings», then «Machine Settings» and «Distribution Confi guration» menus.
From the
tab, select your product from the
Then adjust the detection threshold from the
If on the contrary you feel that the seeding controller is too sensitive, then you can reduce the detection threshold for the relevant
product.
In all cases, it is up to the user to check that the sowing controller is active and has a detection threshold
conditions before starting any sowing job.
Product
Factory setting (%)
Wheat
Barley
Oat
Peas
Horse beans
Rye
Rye-grass
Lucern
Linseed
Rape
Clover
Phacelia
Sorghum
Sunfl ower
Maize
Nitrogen fertilisers
Phosphorous fertilisers
Micro-pelletised fertilisers
Slug pellets
Soy
Buckwheat
Mustard
Triticale
Lupin
This table is provided as an indication only as activation or deactivation is linked to the dosage but also to forward
movement speed during sowing. You may therefore observe diff erences between actual data and the data seen in this
table.
The seeding controller makes allowance for factors such as forward movement speed when operating.
As the forward movement speed may vary, the seeding controller may activate or deactivate during seeding.
Every controller deactivation always comes with an alert.
If you encounter an unstable situation or if you often receive controller deactivation alerts, then there are two solutions:
1- Stabilise the forward movement speed
2- Manually disable the seeding controller using the
When performing «Multi-Product» seeding, the seeding controller is active if all of the products used can be detected.
)
box.
fi eld.
Detection
capacity
5
YES
60
YES
180
YES
1
YES (with limitations)
1
NO
180
YES
170
YES
200
NO
10
YES
5
YES (with limitations)
170
YES
10
YES
18
YES
1
NO
80
NO
200
YES
140
YES
-
NO
1
NO
5
YES
40
YES
1
YES (with limitations)
9
YES
1
NO
button.
is displayed alongside the relevant seeding
set for the product used
Product
Factory setting (%)
Radish
1
Rape
1
Spelt
60
Cocksfoot
20
Bromine
20
Fescue
110
Moha
60
Hemp
60
Timothy seed
180
Vetch
1
Fenugreek
40
Grass pea
1
Lentil
20
Trefoil
140
Nyjer
1
Camelina
1
Oil poppy
8
Sainfoin
6
Millet
10
5
EN
suited to sowing
from the
suited to sowing
Detection
capacity
NO
NO
YES
YES (with limitations)
YES
YES
YES
YES
NO
NO
YES
NO
YES
YES
YES
NO
YES (with limitations)
YES
YES