Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch EPS 205 Originalbetriebsanleitung Seite 64

Vorschau ausblenden Andere Handbücher für EPS 205:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
64 | EPS 205 | Maintenance
6.2.6
Changing test oil
!
Before changing the test oil, the EPS 205 must be
switched off and disconnected from the three-phase
AC network.
!
During use, the test oil is subject to the effects of
evaporation, temperature, pressure, oxidation and
the impact of foreign matter. Regular checking is
therefore essential to ensure compliance with the
necessary test oil quality standard when checking
nozzle-and-holder assemblies and injectors. The
test oil must always be replaced if it is considerably
darker than in the as-new condition. Contaminated
test oil can result in biased measured values and
damage both the EPS 205 and injectors/nozzle-and-
holder assemblies during testing.
Authorized types of test oil:
Type
DIVINOL Calibration Fluid 2928V3
Procedure:
1. Switch off the EPS 205.
2. Disconnect the EPS 205 from the three-phase
AC network.
3. Unscrew the bolts (8x) securing the left housing
cover (Fig. 42, item 6).
4. Detach the housing cover (Fig. 42, item 5).
5. Unscrew the ground cable at the housing side panel
(Fig. 42, item 7).
!
Test oil starts to run through the hose immediately
after inserting the quick-release coupling at the
EPS 205. Always place the end of the hose in the oil
collector beforehand.
6. Place the end of the 1.5 m hose (Fig. 42, item 4;
1 680 712 283) without quick-release coupling in the
oil collector (Fig. 42, item 3).
7. Insert the 1.5 m hose with quick-release coupling
(1 680 712 283) in the quick-release coupling of the
test oil tank (Fig. 42, item 1).
 Test oil runs into the oil collector.
|
1 689 989 185
2018-03-24
6
5
Manufacturer
Zeller+Gmelin GmbH &
Fig. 42:
Co. KG
1 Test oil tank quick-release coupling
2 Settling chamber quick-release coupling
3 Oil collector
4 Hose
5 Housing cover
6 Bolts (8x)
7 Ground cable
8 Oil cooler quick-release coupling
8. Once the test oil has been drained out of the tank,
9. Once the test oil has been drained out of the
10. Once the test oil has been drained out of the oil
11. Clean the test oil tank with a clean cloth.
12. Screw on the ground cable at the housing cover.
13. Fit and screw on the housing cover.
!
14. Pour fresh test oil (ISO 4113) very slowly and
15. Pour in test oil until it is above the mark on the oil
"
7
8
4
Draining test oil
insert the hose in the settling chamber quick-release
coupling (Fig. 42, item 2).
 Test oil from the settling chamber runs into the
oil collector.
settling chamber, insert the hose in the oil cooler
quick-release coupling (Fig. 42, item 8).
 Test oil from the oil cooler runs into the oil col-
lector.
cooler, detach the hose from the quick-release
coupling.
If it is poured in too quickly, the test oil may run out
at the turned-up flushing drain (Fig. 3, item 6) or at
the connection for external extraction (Fig. 1, item 4).
carefully into the jet chamber (Fig. 3, item 4). The
capacity of the test oil tank is approx. 6.5 liters.
level indicator (Fig. 1, item 8).
This completes changing of the test oil.
2
1
3
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis