Herunterladen Inhalt Inhalt Diese Seite drucken

Sony LT 100 Gebrauchsanweisung Seite 64

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Item
Addition and
subtraction function
Alarm
Main unit
Counter board
Chassis ground
Temperature range
Power supply
Power consumption Max. 60 VA (when measuring unit and optional boards are installed)
Weight Approx.
Environmental
conditions
Accessories
Optional accessories
Options
58
A+B setting enabled on one of the counter boards; A-B, B-A supported by direction setting
LCD display and external output when a measuring unit alarm occurs, measuring unit is not
connected (broken wire) or a data storage error occurs
Display selection status, BCD settings (when BCD board is connected), communication parameters
(when RS-232C board is connected)
Resolution, direction, current value, comparator value, preset value, display mode
Insulated from circuit (signal) ground
0 to 40 °C (32 to 104 °F) for operation, –20 to 60 °C (–4 to 140 °F) for storage
Rating: 100 to 230 V AC (allowable range: 90 to 250V AC), 50/60 Hz
4.5 kg (when all the optional boards which can be accommodated are installed)
• Indoor use only
• Maximum operating altitude 2,000 m (6,500 ft) • POLLUTION DEGREE 2
Instruction mannual .................................................................................. 1 set
Power cord ................................................................................................ 1
Earth wire .................................................................................................. 1
Mounting plates (for mounting in a panel) ................................................ 2
Overall I/O output connectror plug ........................................................... 1
Rubber feet ................................................................................................ 4 pcs
Mounting screws
For rubber feet (M3 × 8) ...................................................................... 4 pcs
For mounting plates (M4 × 8) .............................................................. 8 pcs
For panel mounting (M5 × 16 with nuts) .............................................. 4 pcs
Counter board
• Output : Minus common; input : plus common ................................... LZ60-P1
• Output : Plus common; input : minus common ................................... LZ60-P2
BCD board
• Output : Minus common; input : plus common ................................... LZ60-B1
• Output : Plus common; input : minus common ................................... LZ60-B2
RS-232C board ..........................................................................................LZ60-C
Detector (for connecting the DT12 series measuring probe) ................... MT10
Digital printer ............................................................................................. P40
Connector cable for personal computer (2 meters long)
• Personal computer side: 9 pin D-sub connector ................................ DZ252
• Personal computer side: 25 pin D-sub connector .............................. DZ253A
Foot switch ................................................................................................ PZ201
Link cable (1 meter long) .......................................................................... LZ61
Extension cables (for link cable and EXT.IN cables)
• 1-meter long cable .............................................................................. CE08-1
• 3-meter long cable .............................................................................. CE08-3
• 5-meter long cable .............................................................................. CE08-5
• 10-meter long cable ............................................................................ CE08-10
• 15-meter long cable ............................................................................ CE08-15
Specification
• INSTALLATION CATEGORY II

Werbung

Kapitel

Inhaltsverzeichnis
loading