4-5. RS-232C board (LZ60-C)

4-6. Function description

4-6-1. Switching the main display

4-6-2. Reset key

16
1 RS-232C
Reset, peak-hold start, setting/recall of preset values, setting the comparator's value,
and selecting outputting the current value/maximum value/minimum value/peak-to-
peak value are corresponded via this connector.
2 LINK IN
Used to link multiple LT100s.
3 LINK OUT
Used to link multiple LT100s.
4 EXT.IN
External input connector for outputting data via the RS-232C connector.
(Refer to P44 "8. RS-232C Interface".)
The main display shows the measured data, various setting data, alarm indication and
other items for the currently selected counter board. Press
contents to those of a different counter board. Also, the main display selection LED
corresponding to the number of the selected counter board lights.
Display unit
Measuring mode
(Current value, maximum value,
minimum value, peak-to-peak value)
Preset mode
(P and the selected digit will flash.)
Error is displayed
RS-232C
LINK IN
EXT . IN
EXT . IN
4
1
2
Operation performed when reset key is pressed
Display is set to zero.
When a preset value has been set this is recalled.
(Display is zero in peak-to-peak value mode.)
Preset value is set to zero.
Error is cleared and then returnes to the measuring
state.
LINK OUT
3
key to switch the display