7.6 Configuration Menu
MM2 Setup Limit - This is a deviation with respect
to the desired dispensing time beyond which the
grinding is adjusted.
MM1 Ref. Q - flow rate expressed in ml/s, which
can be set through self-learning after 5 coffees
or by entering the value, from a min/max that
can be set.
MM2 Ref. Q - flow rate expressed in ml/s, which
can be set through self-learning after 5 coffees
or by entering the value, from a min/max that
can be set.
MM1 Reference Sel. - selection of the reference
for calculating the average for the MM1 grinding
machine;
from a min/max that can be set.
MM2 Reference Sel. - selection of the reference
for calculating the average for the MM2 grinding
*)
.
machine
(
MM1 Correction Dose: percentage change of the
coffee dose with each movement of the grinders,
in relation to each recipe associated with
MM1; from a min/max that can be set.
MM2 Correction Dose: percentage change of the
coffee dose with each movement of the grinders,
in relation to each recipe associated with
MM2.
MM1 Productivity - MM1 grinder productivity
parameter, relative to coffee consumption,
calculated based on grinding time in [g/s].
MM2 Productivity - MM2 grinder productivity
parameter, relative to coffee consumption,
calculated based on grinding time in [g/s].
Optional MM3 Productivity - MM3 productivity
parameter, relative to coffee consumption,
calculated based on grinding time in [g/s].
Soluble dispenser productivity - Dispenser
productivity parameter, relative to consumption
of soluble powder, calculated based on time the
dispenser is activated in [g/s].
Mov enablement . beak -
see the paragraph "Mov enablement . beak" below.
Delivery spout movement sensitivity - indicates
the variable sensitivity from a min/max that can
be set. See the section "Delivery spout movement
sensitivity" in the pages below.
Water Input Temperature - indicates the mains
*)
(
temperature, from a min/max that can be set.
Power Supply Voltage - indicates the power
supply voltage, from a min/max that can be set.
This parameter is used to calibrate the algorithm
(boiler heating power).
Boiler Upkeep Threshold - indicates the
maintenance threshold as a percentage of the
heating element relative to the set temperature.
When the parameter is set to 0, the check is
deactivated (service boiler can always operate),
100 means it is always activated (e.g. always
75%-25%).
Milk Pipe Emptying Time - indicates the emptying
of the milk pipe after dispensing, from a min/max
that can be set.
Pressure reset cycle -
activated, the cycle is automatically carried out
by the machine prior to each dispensing of milk.
Drawer empty confirmation -
NO: if active the grounds drawer is considered
empty only if the operator confirms it using the
Customer Programming - programming by the
customer:
Recipes per Page - indicates the number of
YES/
NO
recipes shown per page, from a min/max that
can be set.
Back to Page One -
if active, after dispensing made on a different page,
the machine automatically returns to page one.
Pre-selection mode -
the paragraph "Pre-selection Mode" below.
Groups mode -
paragraph "Groups Mode" below.
Repetition selector activated -
NO: if activated, allows the possibility of booking
dispensing to be deactivated.
Stop button activated -
activated, it is possible to disable the possibility
of stopping beverage dispensing.
Show dispensing progress -
NO: see the paragraph "Show Dispensing
Progress" below.
Coffee dispensing time visible -
YES/
NO: if
dispensing panel.
See paragraph "Coffee dispensing time visible" below.
81 EN
icon. The grounds count is also reset.
YES/
NO
YES/
YES/
YES/
YES/
NO: coffee dispensing time displayed in the
YES/
NO:
NO: see
NO: see the
YES/
NO: if
YES/
YES/