Servicing

9 Servicing

9.1 Important notes

Regular servicing is essential in order to ensure that the
device remains in safe working order, à „Maintenance
schedule" on page 26.
CAUTION
Crush hazard when jaws close.
f Do not insert ingers between top and bottom jaws and
do not keep your inger on the trigger.
f Always keep the power pack CPK switched OFF while
servicing is in progress.
CAUTION
Crush hazard due to moving/rotating parts when service
covers are open.
f Do not insert ingers underneath the drum and do not
keep your inger on the trigger.
f Always keep the power pack CPK switched OFF while
servicing is in progress.

9.2 Spare parts and accessories

9.2.1 Spare parts

Spare parts and accessories can be ordered directly from
your national HellermannTyton representative,
à separate spare parts list.
Name
Power pack CPK
Power pack CPK with control box
Tie advancer
Case for AT2000 CPK
USB cable A/B, 1.8 m
Connecting cable, 2 m
Connecting cable, 5 m
Power-supply cable
Operating Instructions for AT2000 CPK
Spare parts list for AT2000 CPK
Safety warnings

9.4 Maintenance schedule

WHEN?
Monthly
Monthly
Approx. every 50,000 bindings
Approx. every 300,000
bindings
Annually or after approx.
1 million bindings
26
Article number
106-00100
106-00110
120-05400
106-00070
123-90028
120-29010
120-29011
120-29005
106-29004
106-29006
106-29003
WHO?
Operator
Operator
Setup specialist
Setup specialist
Setup specialist

9.2.2 Accessories

HellermannTyton offers the following accessories for the
AT2000 CPK; these accessories can be ordered at any
time as need arises:
Name
Bench mount kit CPK
Overhead suspension CPK
Suspension bow CPK
Balancer
Foot-operated switch

9.3 Servicing by manufacturer

It is advisable to have the AT2000 CPK serviced by
HellermannTyton once a year or after every approx.
1 million bindings. This will allow the AT2000 CPK to be
checked and updated to the latest modiication status.
Service contact addresses for all countries are posted on
the website:
www.HellermannTyton.com
WHAT AND HOW?
f Check the top jaw, à „Maintenance jobs" on page 27.
f Check the tie advancer, à „Export process data via power
pack CPK" on page 21.
f Check the end cap and, if necessary, change the cutter,
à „Check end cap" on page 27.
f Change the tie advancer, à „Export process data via power
pack CPK" on page 21.
f Change the top jaw, à „Maintenance jobs" on page 27.