Service menu
6.3 Main menu
Bindings cannot be triggered while you are navigating in the
main menu. The
Signal
blue.
f Press the Enter button.
; The
Main menu
appears on the display.
Main menu
Languages
Status
Settings
Contact
Back

6.4 Languages menu

You use the
Languages
the menus.
Languages
Deutsch
English
Italiano
Français
Türkçe
Polski
Español
f Use the Select button to select the language of your
choice.
f Press the Enter button.
; The display switches to the language you selected.

6.5 Status menu

The
Status
menu shows you the following status readings.
Status
Counter reading
00070725
Tool software
1.17
Power-pack SW
1.04
Serial number
00000013
Temperature
26
Humidity
32
Last service
04.07.2013
Cntr.rdng.lastSer
0000000
14
LED on the power pack CPK shows
menu to select the language for

6.6 Settings menu

You use the
Settings
menu to set important parameters
of the AT2000 CPK.
Access to the
Settings
menu is protected by a three-digit
ment software, à „Changing the access code in the
access code that can be changed in the HT Data Manage-
AT2000 CPK" on page 18. The default access code is 000.
f Use the Select button in the
Settings
menu.
f Press the Enter button.
; The prompt for the access code appears on the display.
Settings
Access code
0 0 0
f Use the Select button to enter each digit of the access
code.
f Press the Enter button to conirm each digit.
; The
Settings
menu appears on the display.
Settings

Force level

Quality

Interruption front sensor
Date / Time

Check of binding

Back
6.6.1 Force level
The
Force level
setting corresponds to the force applied
by the AT2000 CPK when binding, and it can be set
from
Level 1
(lowest force) to
Settings
Force level
Level
1
Level
2
Level
3
Level
4
Level
5
Back
f Use the Select button to select the force level of your
choice.
f Press the Enter button.
; The setting changes to the level you selected.
AT2000 CPK• Operating Instructions • 04-2015 • 106-29004
Main menu
to select the
Level 5
(highest force).