Installation and connection

4.1

Distances and tolerances

During assembly, make sure that the sensor head is
correctly positioned over the magnetic tape. The distances
and tolerances must be complied with to ensure the
correct function and linearity class of the system specific to
the application.
4.1.1

Linear application

–Roll
+Roll
5
5
45
35.2
Fig. 4-1:
Distances and tolerances with linear applications
8
english
Active measuring surface
Free area of magnetizable
material
Direction of travel
Forwards, A (Sin) before B
(Cos), SSI or BiSS position
increasing with rising output,
decreasing with falling
output
60.1
Z
Distances/angles
Z
0.2...0.8 mm (0.05...0.65 mm
(sensor/magnetic
with cover strip), optimal
tape gap)
measurement at 0.4 mm
(0.25 mm with cover strip)
Y (side offset)
3±0.5 mm
Pitch
≤ ±0.5°
Yaw
≤ ±0.2°
Roll
≤ ±0.5°
Tab. 4-1:
Angles, distances, and tolerances with linear applications