1

Notes to the user

1.1
Validity
This guide describes the construction, function and
installation options for the BML absolute magnetically
coded position measuring system. It applies to types
BML-S1G0-B/S7_ _-M5E_-_0-S284 (for linear and
arched applications) and
BML-S1G0-B/S7_ _-M5E_-_0-SA26-S284 (for linear,
arched, and rotative applications), see Type code
breakdown on page 34.
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the position
measuring system.
1.2

Symbols and conventions

Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3

Scope of delivery

Sensor head
Condensed guide
Two insulators
The magnetic tapes are available in different
versions and must be ordered separately.
1.4

Approvals and markings

UL approval
File no.
E227256
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
www.balluff.com
The transducer meets the requirements of the following
product standard:
EN 61326-2-3 (noise immunity and emission)
Emission tests:
RF emission
EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Electrical fast transients (burst)
EN 61000-4-4
Surge
EN 61000-4-5
Conducted interference induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
1.5

Abbreviations

BEF
Balluff exactness factor
BiSS
Bi-directional synchronous serial interface
CDM
Control Data Master
CDS
Control Data Slave
CRC
Cyclic redundancy check
EDS
Electronic Data Sheet
EW event
Errors/warnings are transferred in the
serial data set.
SSI
Synchronous Serial Interface
1.6

Software

XML file via download on the Internet at
www.balluff.com or e-mail to
service@balluff.de.
Severity level 4
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 5