BAE SA-OH-063-_P-DP02 / BAE SA-OH-063-_P-S75G
Photoelectric Sensors
5
Installation and connection
5.1
Installation
For dimensions, see Fig 4-1 on page 8.
The following mounting types of the sensor amplifiers are
available:
–
Simple clamp mounting on DIN rail with dimension of
DIN 35 mm or 15 mm.
–
Clamp mounting on optional DIN rail adapter by means
of M3 threaded screws.
► Place the device on the DIN rail adapter as shown.
Connect cable.
Fig 5-1:
Installation of amplifier
5.2
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a plug connection. The connection or pin
assignments for the respective version can be found in
Tab. 5-1 to Tab. 5-2.
See the information about Shielding and cable
routing.
5.2.1
Supply (plug connection)
Fig 5-2:
Pin assignment, M8 plug connector (top view of supply
plug connector)
Pin
...-NP-S75G
1
L+ (operating voltage +, 15...30 V DC)
2
External teach input
3
L− (operating voltage −, 0 V, GND
4
NPN output
Reference potential for supply voltage and EMC-GND.
1)
Tab. 5-1:
Pin assignment, M8 plug connector
10
english
5.2.2
BN brown
WH white
BU blue
BK black
Reference potential for supply voltage and EMC-GND.
1)
Tab. 5-2:
5.2.3
Fig 5-3:
Reference potential for supply voltage and EMC-GND.
1)
Tab. 5-3:
5.3
The BOH sensor cable is shielded and should not
be extended.
The maximum supply cable length is 20 m.
...-PP-S75G
)
1)
PNP output
Supply (cable connection)
Color
...-NP-DP02
L+ (operating voltage +, 15...30 V DC)
External teach input
L− (operating voltage −, 0 V, GND
NPN output
Connection assignment, cable
Sensor
Pin assignment (top view of sensor connector)
Pin
Signal
1
LED+ (transmitter)
3
FT+ (receiver/phototransistor)
4
GND
(0 V/cable shielding)
1)
Pin assignment, sensor connector
Shielding and cable routing
...-PP-DP02
)
1)
PNP output