Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Ambient Conditions; Supply Voltage - Balluff BML-S1G0-B7-M5E-0-S284 Serie Betriebsanleitung

Absolutes magnetkodiertes wegmesssystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BML-S1G0-B/S7_ _-M5E_-_0-(SA26-)S284
Absolute Magnetically Coded Position Measuring System
9

Technical Data

The information here comprises typical values at room
temperature in conjunction with magnetic tape
BML-M02-A55-A... and BML-M03-A55-A... with a gap of
0.4 mm over the magnetic tape (without cover strip).
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
9.1
Accuracy
Position resolution
Absolute
(BML-S1G0-B/S...)
BML-S1G0-_ _ _C-...
BML-S1G0-_ _ _D-...
BML-S1G0-_ _ _E-...
BML-S1G0-_ _ _F-...
BML-S1G0-_ _ _G-...
Analog, incremental
real-time signal
(BML-S...-M5EA-...)
Digital, incremental real-
time signal
(BML-S...-M5EQ-...)
Repeat accuracy
Hysteresis
Max. non-linearity of sensor
head
Max. non-linearity of entire
system (sensor head +
magnetic tape)
Temperature coefficient of
the entire system
Movement speed
28
english
0.9765625 µm
(1000/1024 µm)
1 µm
2 µm
5 µm
10 µm
Period 2 mm
Resolution (edge distance)
as absolute
< 1 μm
≤ 2 μm
±2 μm
±20 μm (BML-M0_-A55...)
10.5 ppm/K
Max. 10 m/s
9.2

Ambient conditions

Operating temperature
Storage temperature
for sensor head
Shock rating
Continuous shock
per EN 60068-2-27
2)
Vibration load
per EN 60068-2-6
2)
Noise
per EN 60068-2-64
2)
Degree of protection per
IEC 60529 (with screwed-on
connector)
External magnetic fields
Humidity
9.3

Supply voltage

Supply voltage
3)
Current draw
4)
Power consumption
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
Switch-on delay (system
ready) after applying supply
voltage
For
: Use in enclosed spaces and up to a height of 2000 m above
1)
sea level.
Individual specifications as per Balluff factory standard, resonances
2)
excluded
For
: The sensor head must be externally connected via a limited-
3)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
4)
Without controller current draw
1)
–20 °C...+70 °C
–25 °C...+85 °C
100 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
20 g, 5...2000 Hz
IP67
– < 30 mT (to avoid
permanent damage)
– < 1 mT (to avoid
influencing the
measurement)
90% RH, condensation not
permitted
5 V ±5% or 10...28 V
220 mA at 5 V supply
voltage
70 mA at 24 V supply
voltage
< 1.5 W + controller power
consumption
No
No
500 V DC
Max. 1000 ms

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis