Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Preparing For Installation; Installation; Electrical Connection - Balluff BES M08EH1-L01C20B-S04G-L04 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BES M08EH1-L01C20B-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
5

Installation and connection

5.1

Preparing for installation

Flush mountable sensors
Flush mountable sensors can be embedded in non-
ferromagnetic materials up to the active surface. This may
result in a reduction of the switching distance (S
installed in non-ferrous metal. The distance to opposite
metal surfaces must be ≥ 3 S
two sensors (for series mounting) ≥ 2 d. In order to be able
to install the sensor in ferromagnetic materials, the guide
value of 1 mm for dimension X applies (see Fig. 5-1).
The deviation in the effective operating distance associated
with the installation is maximum 10 %.
Active surface
Fig. 5-1:
Flush mounting with dimension X
Non-flush mountable sensors
Non-flush mountable sensors can usually be identified by
their caps, as they do not have a metal housing in the area
around the active surface. The active surface must
protrude ≥ 2 S
from the metal mounting medium. The
n
distance to opposite metal surfaces must be ≥ 3 S
the distance between two sensors ≥ 3 d.
5.2

Installation

For dimensions, see Fig. 4-1 on page 8.
► Install the sensor so that it is protected from
electromagnetic fields and mechanical damage.
10
english
) when
n
and the distance between
n
and
n
5.3

Electrical Connection

1
2
4
3
Fig. 5-2:
Plug layout (top view of M12 plug on sensor)
Pin Signal
1
L+ (Operating voltage +, SIO 10...30 V,
IO-Link 18...30 V)
2
I/Q (digital input / digital output)
3
L− (Operating voltage −)
4
C/Q (IO-Link communication / digital output in SIO
mode / digital input)
Tab. 5-1:
Pin assignment
5.4

Shielding and cable routing

Cable length
For IO-Link operation, the maximum cable length is 20 m.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis