Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Installation; Electrical Connection; Shielding And Cable Routing - Balluff BAE SA-OH-061-UA-DP02 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BAE SA-OH-061-UA-DP02:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BAE SA-OH-061-UA-... / BAE SA-OH-062-IC-...
Photoelectric Sensors
5

Installation and connection

5.1

Installation

For dimensions, see drawings on page 8.
The following mounting types of the sensor amplifiers are
available:
Simple clamp mounting on DIN rail with dimension of
DIN 35 mm or 15 mm.
Screw mounting by means of through holes for M3
screws.
Clamp mounting on DIN rail adapter by means of M3
screws.
Place the device on the DIN rail adapter as shown. Con-
nect the cable according to the connection table.
Fig. 5-1:
Mounting the amplifier
10
english
5.2

Electrical connection

4-pin (supply)
Fig. 5-2:
Electrical connection for the amplifier (4-pin connection
only on variant -S75G)
Pin
Signal
4-pin (supply) (plug variant)
Operating voltage: 15...30 V
1
VDC
Max. current consumption: 45mA
– UA-S75G
AGND
– IC-S75G
2
– UA-S75G-SA3
IN
– IC-S75G-SA3
3
GND
Operating voltage: 0 V
– UA-S75G
– UA-S75G-SA3
4
AOUT
– IC-S75G
– IC-S75G-SA3
5-pin (supply) (cable variant)
Operating voltage: 15...30 V
Braun
VDC
Max. current consumption: 45mA
– UA-DP02
Weiß
AGND
– IC-DP02
Blau
GND
Operating voltage: 0 V
– UA-DP02
Schwarz AOUT
– IC-DP02
Rosa
IN
Input (external teach, ...)
3-pin (sensor) (all versions)
1
LED+ Emitter (LED)
3
PHT+ Receiver (Photo transistor)
4
GND
0 V / Cable shielding
Tab. 5-1:
Pin Assignment
Factory setting
Standard Power, Standard Speed, Syncmode Off,
Input Off
5.3

Shielding and cable routing

The BOH sensor cable is shielded and should not be
extended.
3-pin (sensor)
Description
0 V
Input
(external teach, ...)
Voltage output:
0...10 V
Current output:
4...20 mA
0 V
Voltage output:
0...10 V
Current output:
4...20 mA

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis