without milled
Protection class
with milled recess
Continuous sound pressure level
Lifting speed
Max. push/pull force
Max. push/pull force in medical
applications
Position signal,
(pulses per mm travel)
Number of Hall sensor channels
Operating conditions
Max. push / pull force
Diagram 1:
depending on the stroke length
3500
3000
2500
2000
1500
1000
500
0
0
200
400
recess
* (Base and application surface is covered completely and without boreholes or
8 mm/s
3000 N / 1000 N*
See "Diagram 1: Max. push / pull force depending on the stroke length".
2000 N / 500 N*
See "Diagram 2: Max. push / pull force depending on the stroke length in medical
In dry rooms at temperatures from +5 deg. C to +40 deg. C, relative humidity from
30 per cent to 75 per cent (no thawing), air pressure 700 hPA to 1060 hPA (up to an
8 mm/s (compressive
force)
16 mm/s (compressive
force)
8/16 mm/s (tensile
force)
600
800
1000
Stroke [mm]
6. Product information
Mono
IP 20*
when using the SyncFlex adapter plate
IP 10
Less than 60 dBA
16 mm/s
1000 N / 1000 N*
1000 N / 500 N*
applications".
* Only in conjunction with the additional assembly / thrust
plate at the bottom installed ex-factory (load type tensile force
must already be considered in the order, cannot be retrofitted
at the customer location)
0
altitude of 3000 m)
Diagram 2:
Max. push / pull force
depending on the stroke length
in medical applications
3500
3000
2500
2000
1500
1000
500
0
1200
0
200
Synchro
8 mm/s
16 mm/s
3000 N / 1000 N*
1000 N / 1000 N*
2000 N / 500 N*
1000 N / 500 N*
2
1
8 mm/s (compressive
16 mm/s (compressive
8/16 mm/s (tensile
400
600
800
1000
Stroke [mm]
1
1
force)
force)
force)
1200
53