Herunterladen Inhalt Inhalt Diese Seite drucken

Assembling The Flushing Extension; Manifold Connection - Ecolab Elados Pump Rack Betriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Installation
5.7.6

Assembling the flushing extension

1.
Isolate the unit from the mains.
2.
Interrupt the fresh water supply.
3.
Loosen the fastening screws on both sides (4 x, Fig. 12 , No. 14) on the fastening
brackets (2 x, Fig. 12 , No. 11).
4.
Remove valve block with spacers.
5.
Loosen end piece ( Fig. 12 , item 12) and pull off.
6.
Fit the flushing extension onto the valve block and push it on until it latches into
position.
7.
Push on the end piece again.
8.
Fasten the valve block with spacers.
9.
Route the coil cable to the terminal box, trim if necessary and isolate the wires.
10. Connect the cable to the terminal box.
11. Put the ELADOS Pump Rack back into operation.
12. Check the valve black for correct functioning.
5.7.7

Manifold connection

Figure
Designation
Suction valve
SAV PPEPKE007
G5/8-G5/8-99
Threaded socket
G1/2i G5/8i PP
Male stud coupling
G1/2 8/12 PP
Suction valve
SAV PVFPKE007
G5/8-G5/8-99
Threaded socket
G1/2i G5/8i PVDF
Male stud coupling
G1/2 8/12 PVDF
417102267 Ver. 04-11.2023
CAUTION!
Check that the O-rings are seated correctly.
Misuse
Alcaline
products
Acidic
products
Material
Connection Article no. EBS No.
PP
8 / 12
PVDF
8 / 12
52
249477
10200140
30190706
10032390
415102370
10022775
249326
10200137
30190707
10032391
415102371
10022785