Installation
5.7.2
EMP III pump – 80 / 120 l/h
Fig. 9: Assembly of the pump connection kit for the EMP III pump (80 / 120 l/h)
1
Hose connector
2
O-ring
3
Union nut
1.
Assemble the hose nozzle with the pre-assembled insert (item 1) and the O-ring
(item 2)
with union nut (item 3) on the suction side pump connection.
2.
Push on the Tygon hose (item 6) and fix in place with the hose clamp (item 4).
3.
Assemble the insert with the pre-assembled male stud coupling (item 2) and union
nut (item 3)on the pressure-side pump connection.
See for pipe assembly:
Ä Chapter 5.7.1 'EMP III pump – 54 l/h' on page 47 .
417102267 Ver. 04-11.2023
4
Hose clamp
5
Insert with pre-assembled male stud coupling
6
Tygon hose