Herunterladen Inhalt Inhalt Diese Seite drucken

Abort Sdo Transfer Request Protocol - TR-Electronic LP-46 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LP-46:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error Causes and Remedies

9.3 Abort SDO Transfer Request Protocol

In the case of an error (SDO Response CCD = 0x80), Abort SDO Transfer Request
Protocol is transmitted instead of the response.
Abort SDO Transfer Request, Server --> Client
Frame Fragment
Data field
Length
Address
Channel
Mailbox Header
Priority
Type
reserved
Quantity
CANopen Header
reserved
Service
Size indicator
Transmission type
SDO
Data record size
reserved
Command
Index
Sub-Index
Abort code
Table 8: Abort SDO Transfer Request
 TR-Electronic GmbH 2013, All Rights Reserved
Page 124 of 128
Data type
Value / Description
WORD
0x0A: Length of the mailbox service data
Source station address, if Master = Client
WORD
Destination station address, if Slave = Client
unsigned:6
0x00, reserved
0x00: Lowest priority
...
unsigned:2
0x03: Highest priority
unsigned:4
0x03: CANopen over EtherCAT (CoE)
unsigned:4
0x00
unsigned:9
0x00
unsigned:3
0x00
unsigned:4
0x02: SDO Request
unsigned:1
0x00
unsigned:1
0x00
unsigned:2
0x00
unsigned:1
0x00
unsigned:3
0x04: Abort Transfer Request
WORD
Object index
BYTE
Object sub-index
DWORD
Abort code
TR-ELA-BA-DGB-0020 v04