8.8 Object 3000h: Status

The status shows whether the magnets are located within the permissible measuring
range. If the error "Number of magnets incorrect" is reported, either no magnets are
installed, at least one magnet is located in the damping zone or the configurated
number of magnets do not agree with the operated number of magnets. No analyzable
measuring signal can be output by the measuring system within the damping zone.
The status for bit 0 and bit 1 is output only if under Object 2004h: Number of enabled
Sensors, the setting "with monitoring" is present.
Index
Description
Data type
Category
Access
PDO mapping
Default

8.9 Object 3001h: Temperature

With this object the current device temperature is output.
Index
Description
Data type
Category
Access
PDO mapping
Value
Printed in the Federal Republic of Germany
01/14/2022
0x3000
Status
UNSIGNED16
Optional
ro
No
0
Bit 0, number of magnets incorrect
Is set if the number of magnets < detected magnets
Bit 1, internal error occurred
Is set if no error-free position output can be guaranteed
Bits 2 to 7, reserved
Bits 8 to 15, corresponds the number of detected magnets / positions
0x3001
Temperature
INTEGER8
Optional
ro
No
Value in °C, HEX-coded