Herunterladen Inhalt Inhalt Diese Seite drucken

Object 2003H: Position Filter; Object 2004H: Number Of Enabled Sensors - TR-Electronic LP-46 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LP-46:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.4 Object 2003h: Position Filter

With the Position filter the output position value can be averaged and results in a small
output jitter.
Index
Description
Data type
Category
Access
PDO mapping
Value
Default

8.5 Object 2004h: Number of enabled Sensors

With this object the number of magnets is defined, with which the measuring system is
to be operated. About the setting possibilities it can be selected, whether the
monitoring is switched on or off:
Index
Description
Data type
Category
Access
PDO mapping
Value
Default
Printed in the Federal Republic of Germany
01/14/2022
0x2003
Position Filter
UNSIGNED8
Optional
rw
No
1 = no averaging,
2 = averaging of 2 values,
4 = averaging of 4 values
8 = averaging of 8 values
1
Monitoring switched off
If the number of defined magnets does not agree with the number of detected
magnets, in the status object 3000h no error message is output.
Monitoring switched on
If the number of defined magnets does not agree with the number of detected
magnets, in the status object 3000h an error message is output.
0x2004
Number of enabled Sensors
UNSIGNED8
Optional
rw
No
0: no monitoring
1-31: Number of magnets, monitoring ON
0
TR-ELA-BA-DGB-0020 v04
 TR-Electronic GmbH 2013, All Rights Reserved
Page 113 of 128

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lp serieLmp serieLa serieLa-46Lmp-30

Inhaltsverzeichnis