Error Causes and Remedies

9.4 Emergency Request Protocol

Emergency messages are triggered if an internal fault occurs. The transmission is
executed via the mailbox interface.
The Emergency Service is used by the server to transmit diagnostic messages to the
client. Each diagnostic event transmitted by the server to the client is also reconfirmed
by transmission of the reset error code when the diagnostic event is no longer present.
Emergency Request, Server --> Client
Frame Fragment
Data field
Length
Address
Channel
Mailbox Header
Priority
Type
reserved
Quantity
CANopen Header
reserved
Service
Error code
Error register
Emergency
Data
reserved
Table 10: Emergency Request
 TR-Electronic GmbH 2013, All Rights Reserved
Page 126 of 128
Data type
Value / Description
n ≥ 0x0A: Length of the mailbox service data
WORD
Source station address, if Master = Client
WORD
Destination station address, if Slave = Client
unsigned:6
0x00, reserved
0x00: Lowest priority
...
unsigned:2
0x03: Highest priority
unsigned:4
0x03: CANopen over EtherCAT (CoE)
unsigned:4
0x00
unsigned:9
0x00
unsigned:3
0x00
unsigned:4
0x01: Emergency
WORD
Error Code
BYTE
Error Register
Error Code 0000-9FFF: Manufacturer-specific error field
BYTE[5]
Error Code A000-EFFF: Diagnostic data
Error Code F000-FFFF: Manufacturer-specific error field
BYTE[n-10]
not yet specified