Herunterladen Inhalt Inhalt Diese Seite drucken

Object 6010H: Preset Values - TR-Electronic LP-46 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LP-46:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.14 Object 6010h: Preset values

The preset function is used to set the measuring system value of the supported
channels to any position value within the range of 0 to measuring length in steps. The
output position value is set to the "Preset value" parameter if writing to this object.
If the value 0xFFFF FFFF (-1) is written, the calculated zero point correction is deleted
(difference between desired preset value and physical measuring system position).
After deletion of the zero point correction, the measuring system outputs its "real"
physical position.
Index
Description
Object code
Data type
Category
Sub-Index
Description
Data type
Category
Access
PDO mapping
Value
Printed in the Federal Republic of Germany
01/14/2022
Danger of physical injury and damage to property due to an actual value
jump during execution of the preset adjustment function!
 The preset adjustment function should only be executed when the
measuring system is stationary, or the resulting actual value jump must be
permitted by both the program and the application!
0x6010
Preset Values
ARRAY
UNSIGNED32
Mandatory
Byte 0
Byte 1
7
0
15
2
to 2
2
0
Number of available channels
UNSIGNED8
Mandatory
ro
No
30
TR-ELA-BA-DGB-0020 v04
Preset Value
Byte 2
8
23
to 2
2
to 2
Byte 3
16
31
24
2
to 2
 TR-Electronic GmbH 2013, All Rights Reserved