Operation setup
Service setup
22
20
Heat
Water temp. for heating ON
21
Outdoor temp. for heating OFF
22
23
 Cooling model only
24
Cool
Water temp. for cooling ON
25
 Cooling model only
26
Auto
27
 Only when the
selection for Tank
is Yes
28
Tank
Floor operation time (max.)
29
Tank heat up time (max.)
30
Tank re-heat temp.
31
32
Pump maximum speed
33
Pump down
34
Dry concrete
35
Service contact
T for heating ON
Heater ON/OFF
(Display only if Cool exist, or else skip)
T for Cooling ON
Outdoor temp. for
(Heat to Cool)
Outdoor temp. for
(Cool to Heat)
Sterilization
Pump maximum speed setup
Pump down ON / OFF
ON (Dry concrete)
Edit (Dry concrete schedule)
Contact 1
Contact 2
Compensation curve
Direct
Heating OFF Temp. setup
T for heating setup
O/D temp for heater ON setup
Heater ON Delay Time
T of target temperature for Heater ON
T of target temperature for Heater OFF
Compensation curve
Direct
T for cooling setup
Heat
Cool change temp. setup
Cool
Heat change temp. setup
Max. operation time for Heat & Cool mode setup
Max. operation time for Tank mode setup
Tank re-heat temp. setup
Sterilization day and temp. and time setup
Air purge
Day and temp. setup
Name and Tel No. setup
Name and Tel No. setup
Compensation
curve setup
Direct temp. setup
Compensation
curve setup
Direct temp. setup