10 Care

To protect the paintwork, avoid leaning anything against
the device or putting objects on the device.
The outdoor components of the heat pump can be wiped
with a damp cloth and commercially available domestic
cleaner.
NOTE
Never use cleaning agents containing sand, soda, acid or
chloride, as these can damage the surfaces.
Under extreme weather conditions (e.g. snow drifts), ice
formation may occur on the air intake and air outlet grids. If
this happens, the ice must be removed from the vicinity of
the intake and air outlet area to ensure that the minimum
air flow is maintained.
Twigs, leaves and dirt accumulated around the device
must be removed at regular intervals.
www.dimplex.de
11 Faults/troubleshooting/
This heat pump is a quality product and is designed for trouble-
free operation. In the unlikely event that a fault should occur,
please inform the responsible after-sales service.
DANGER!
Risk of death due to fire or explosion.
The device contains flammable odourless refrigerant (R290).
In case of leakage, the refrigerant can mix with the ambient air
and form a flammable atmosphere.
Work on the heat pump is only to be carried out by people
with the knowledge set out in Fig. 1.1 on page 4.
Avoid ignition sources (naked flames, hot surfaces,
electrical equipment with ignition sources and static
discharge) and fire loads in the danger zone.
Before and when opening the device, check the working
area and the interior of the device for the presence of
R290 using the refrigerant detector. The detector and all
other tools must be suitable for the R290 refrigerant,
produce no sparks and must be appropriate sealed or
explosion protected and calibrated.
Cordon off the area around the device to prevent
unauthorised access.
The leakage tightness of the refrigerant circuit must be
tested after all assembly work is complete and the
external power supply (load and control voltage) has been
connected.
DANGER!
Risk of death due to electric shock.
If the device is not fitted with all covering panels there is a risk
of electric shock.
Disconnect all electric circuits from the power source
prior to opening the device.
After disconnecting the power supply, you have to wait 5
minutes before all components are de-energised.
DANGER!
Risk of death due to lightning.
Standing outside during a storm can result in a risk of death.
Do not stand in the immediate vicinity of the heat pump.
DANGER!
Risk of death due to electric shock.
There is a risk of death when working on the electrical
equipment or live components in wet weather conditions
(precipitation, snow)
In case of precipitation, the device must be properly
closed.
NOTE
Only software that is authorised and approved by the
manufacturer can be installed on the machine's control
system.