Only connect the Product to the charging stations as indicated in
the Specification section.
Use the Product within the operating range only. The operating
range is specified in the Specification section.

Transport and Storage

Please keep the original packaging for future transport (for example, if
calibration is necessary). Any transport damage due to faulty packaging will
be excluded from warranty claims.
The adapter must be stored in dry, closed areas. In case of an adapter being
transported in extreme temperatures, a minimum recovery time of 2 hours is
required prior to any operation.
Available measurements and product description
PE Pre-Test (potential presence of dangerous voltage at PE terminal
by mistake) – touch electrode and LED.
Phase indicator (presence of all three phase voltages measured to N)
– three LED's.
PP State simulation (open, 13 A, 20 A, 32 A, 63 A) – rotary switch.
CP State simulation (state A, B, C
CP Error state "E" simulation (CP signal short-circuited to PE)
– push button.
PE Error state "F" (Earth Fault) simulation (interruption of PE
conductor) – push button.
Measurements on live conductors (L1, L2, L3 and N) and on PE
conductor – five 4 mm safety sockets for connection to Installation
Testers (for example, FLUKE 166x series). This allows safety
measurements via the measuring terminals like:
- earth bond
- insulation
- loop/line impedance
- RCD trip test
Test of CP signal – two 4 mm safety sockets for connection to a
multimeter or oscilloscope.

Optional Accessories

FEV300-CON-TY1 Type 1 Plug for Test Adapter EV Charging
FEV300-CON-TY2 Type 2 Plug for Test Adapter EV Charging
3
, D
) – rotary switch.