Konfiguration und Programmierung
AC500-S-Bibliotheken > SafetyBlocks_PLCopen_AC500_v22.lib
Falsche Muting-Sequenzen:
Zustand 8000 - (MutingEnable = FALSE, wenn Muting-Sequenz startet) OR
((MS_11 OR MS_12) AND (MS_21 OR MS_22)) OR
(R_TRIG at MS_11 AND MS_12 AND NOT R_TRIG at MS_12) OR
(R_TRIG at MS_12 AND MS_11 AND NOT R_TRIG at MS_11) OR
(R_TRIG at MS_21 AND MS_22 AND NOT R_TRIG at MS_22) OR
(R_TRIG at MS_22 AND MS_21 AND NOT R_TRIG at MS_21) OR
((MS_11 AND NOT R_TRIG at MS_11) AND (MS_12 AND NOT R_TRIG at MS_12)) OR
((MS_21 AND NOT R_TRIG at MS_21) AND (MS_22 AND NOT R_TRIG at MS_22))
Zustand 8011 - NOT MutingEnable OR MS_11 OR MS_12 OR NOT MS_21
Zustand 8311 - NOT MutingEnable OR NOT MS_12 OR MS_21 OR MS_22
Zustand 8012 - NOT MS_11 OR NOT MS_12
Zustand 8021 - R_TRIG at MS_11 OR R_TRIG at MS_12 OR R_TRIG at MS_21 OR R_TRIG at MS_22
Zustand 8014 - NOT MS_11 OR NOT MS_12 OR NOT MS_21
Zustand 8314 - NOT MS_11 OR NOT MS_12 OR NOT MS_22
Zustand 8122 - NOT MutingEnable OR MS_11 OR MS_12 OR NOT MS_21
Zustand 8422 - NOT MutingEnable OR MS_11 OR MS_12 OR NOT MS_22
Zustand 8121 - NOT MS_21 OR NOT MS_22
Zustand 8112 - R_TRIG at MS_11 OR R_TRIG at MS_12 OR R_TRIG at MS_21 OR R_TRIG at MS_22
Zustand 8114 - NOT MS_21 OR NOT MS_22 OR NOT MS_11
Zustand 8414 - NOT MS_21 OR NOT MS_22 OR NOT MS_12