4. Technical Data
4. Technical Data
4.1. Technical Data
Nomencla-
ture
P
ac,r
4
V
ac,r
I
acmax
cosphi
f
r
V
dc,r
V
mppmin
V
mppmax
V
dcmax
V
dcstart
V
dcmin
I
dcmax
Table 4.1: Specification for Danfoss TLX Inverters
1) According to FprEN 50524.
2) For fixed systems with semi-optimal conditions.
3) At identical input voltages. At unequal input voltages V
20
Parameter
1)
AC
Max/Nom power AC
AC Voltage range (P-E)
Nominal current AC
Max current AC
AC current Distortion (THD%)
Power factor
ac,r
"Connecting" power loss
Night-time power loss (off grid) <5 W
Grid frequency
DC
Nominal power DC
Max recommended PV power at
2)
STC
Nominal voltage DC
-
MPP voltage - nominal power
MPP efficiency
Max DC voltage
Turn on voltage DC
Turn off voltage DC
Max. current DC
Max. short circuit current DC at
STC
Min. on grid power
Efficiency
Max efficiency
Euro efficiency, V
dc,r
Other
Dimensions (L,W,H)
Mounting recommendation
Weight
Acoustic Noise level
Operation temperature range
Nom. temperature range
Storage temperature
Overload operation
Overvoltage category
Functional Safety
Islanding detection - loss of
mains
Voltage Magnitude
Frequency
DC content of AC current
Insulation resistance
RCMU - Type B
Indirect contact protection
Short circuit protection
TLX 10 k
TLX 12.5 k
10000 W
12500 W
± 20 %
3x230 V
3x230 V
3 x 15 A
3 x 19 A
3 x 15 A
3 x 19 A
< 5%
< 5%
>0.97 at 20 % load
>0.97 at 20 % load
10 W
10 W
<5 W
50 ± 5 Hz
50 ± 5 Hz
10300 W
12900 W
11800 Wp
14700 Wp
700 V
700 V
3)
430-800 V
430-800 V
99.9 %
99.9 %
1000 V
1000 V
250 V
250 V
250 V
250 V
2x12 A
3x12 A
2x12 A
3x12 A
20 W
20 W
98%
98%
97%
97.3%
700x525x250 mm
700x525x250 mm
Wall bracket
Wall bracket
35 kg
35 kg
56 dB(A)
56 dB(A)
-25..60 °C
-25..60 °C
-25..45 °C
-25..45 °C
-25..60 °C
-25..60 °C
Change of operating
Change of operating
point
point
Class III
Class III
Three phase monitoring
Three phase monitoring
(ROCOF)
(ROCOF)
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Yes (class I, grounded)
Yes (class I, grounded)
Yes
Yes
lies between 250-430 V depending on total input power.
mppmin
L00410309-03_2q
TLX 15 k
15000 W
± 20 %
± 20 %
3x230 V
3 x 22 A
3 x 22 A
< 5%
>0.97 at 20 % load
10 W
<5 W
50 ± 5 Hz
15500 W
17700 Wp
700 V
430-800 V
99.9 %
1000 V
250 V
250 V
3x12 A
3x12 A
20 W
98%
97.4%
700x525x250 mm
Wall bracket
35 kg
56 dB(A)
-25..60 °C
-25..45 °C
-25..60 °C
Change of operating
point
Class III
Three phase monitoring
(ROCOF)
Included
Included
Included
Included
Included
Yes (class I, grounded)
Yes