Herunterladen Inhalt Inhalt Diese Seite drucken

Explanation Of Symbols; Technical Data - REMS Multi-Push SL Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Multi-Push SL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
eng
c) Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power source, picking up or carrying the tool. Carrying power
tools with your finger on the switch or energising power tools that have the switch
on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on. A
wrench or a key left attached to a rotating part of the power tool may result in
personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This enables
better control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewellery. Keep your hair,
clothing and gloves away from moving parts. Loose clothes, jewellery or long
hair can be caught in moving parts.
4) Power tool use and care
a) Do not force the power tool. Use the correct power tool for your application.
The correct power tool will do the job better and safer at the rate for which it was
designed.
b) Do not use the power tool if the switch does not turn it on and off. Any power
tool that cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source before making any adjustments,
changing accessories, or storing power tools. Such preventive safety meas­
ures reduce the risk of starting the power tool accidentally.
d) Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power
tool. Power tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tool's
operation. If damaged, have the power tool repaired before use. Many
accidents are caused by poorly maintained power tools.
f) Use power tools, accessories and insert tools etc. according to these
instructions. Take the working conditions and activity being performed into
consideration. The use of power tools for purposes for which they are not
intended can lead to dangerous situations.
g) Keep handles dry, clean and free from oil and grease. Slippery handles prevent
safe handling and control of the power tool in unexpected situations.
5) Service
a) Have your power tool serviced by a qualified repair person using only
identical replacement parts. This will ensure that the safety of the power tool
is maintained.
Safety notes for the electronic flushing and
pressure testing unit with compressor
WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
● Never use the power tool without the PRCD fault current circuit breaker
included. The use of a fault current circuit breaker reduces the risk of electric
shock.
● The power tool develops very high pressures, in applications with compressed
air of up to 1 MPa/10 bar/145 psi and in applications with water of up to 4
MPa/40 bar/580 psi. So be very careful. Keep third parties away from the work
area when working with the electrical device.
● Do not use the power tool if it is damaged. There is a danger of accident.
● Examine the high-pressure hoses for damage every time before using.
Damaged high­pressure hoses can burst and cause injury.
● Only use original high-pressure hoses, fittings and couplings for the power
tool. This ensures that the safety of the device is maintained.
● Apply the power tool horizontally and dry for operation. Penetration of water
into the electrical device increases the risk of electric shock.
● Do not aim liquid jet at the power tool, not even for cleaning. Penetration of
water into the electrical device increases the risk of electric shock.
● Do not suck up inflammable or explosive liquids, for example petrol, oil,
alcohol, solvent, with the power tool. The fumes or liquids can ignite or explode.
● Do not operate the power tool in rooms where there is a risk of explosion.
The fumes or liquids can ignite or explode.
● Protect the power tool against frost. The device could be damaged. Let the
power tool run empty for about 1 minute, if necessary, to drain off remaining
water.
● Never let the power tool operate unattended. Switch the power tool off at
the On/Off switch (4) and pull out the mains plug for longer work breaks.
Electrical devices can cause hazards which lead to material damage or injury
when left unattended.
● Do not operate the power tool on a closed pipe system for a prolonged
period of time. The power tool could be damaged by overheating.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the power tool
safely may not use this power tool without supervision or instruction by a
responsible person. Otherwise there is a risk of operating errors and injuries.
● Only allow trained persons to use the power tool. Apprentices may only use
the power tool when they are over 16, when this is necessary for their training
and when they are supervised by a trained operative.
● Check the power cable of the electric al device and extension leads regularly
for damage. Have these renewed by qualified experts or an authorised REMS
customer service workshop in case of damage.
● Only use approved and appropriate marked extension leads with a sufficient
cable cross-section at least with the protection class approved in 1.4.
Electrical data. Use extension leads up to a length of 10 m with cable cross­sec­
tion 1.5 mm², from 10 – 30 m with cable cross­section 2.5 mm².

Explanation of symbols

WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Use eye protection
Use hand protection
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark

1. Technical data

Use for the intended purpose
WARNING
Only use the power tool for the purpose intended. Failure to do so can result in death
or severe injury.
REMS Multi-Push is intended for
●  flushing drinking water installations with water in accordance with EN
806-4:2010 and information leaflet T 84-2004 "Flushing, Disinfection and Commis-
sioning of Drinking Water Installations" of the German Central Association for
Sanitary, Heating and Air Conditioning and for flushing radiators and area heating 
systems.
●  flushing drinking water installations with a water/air mixture with intermit-
tent compressed air in accordance with EN 806-4:2010 and information leaflet 
T 84-2004 "Flushing, Disinfection and Commissioning of Drinking Water Instal-
lations" of the German Central Association for Sanitary, Heating and Air Condi-
tioning and for flushing radiators and area heating systems.
●  flushing pipe systems with a water/air mixture with constant compressed air
●  disinfection, cleaning and preservation: disinfection of drinking water instal-
lations  in according  with EN 806-4:2010  and information  leaflet T 84-2004 
"Flushing, Disinfection and Commissioning of Drinking Water Installations" of the
German Central Association for Sanitary, Heating and Air Conditioning and other
pipe systems. cleaning and preservation of radiators and area heating systems.
Use of different additives for disinfection, cleaning and preservation for different
applications with a feed unit for feeding in the additives.
●  leak testing of drinking water installations with compressed air in accordance
with information leaflet T 82-2011 "Leak Testing of Drinking Water Installations" 
of the German Central Association for Sanitary, Heating and Air Conditioning and
pressure and leak testing of other pipe systems and vessels.
●  load testing of drinking water installations with compressed air in accordance
with information leaflet T 82-2011 "Leak Testing of Drinking Water Installations" 
of the German Central Association for Sanitary, Heating and Air Conditioning and
pressure and load testing of other pipe systems and vessels.
●  hydrostatic pressure testing of drinking water installations with water in
accordance with EN 806-4:2010, Test Method A and for pressure and leak
testing of other pipe systems and vessels.
●  hydrostatic pressure testing of drinking water installations with water in
accordance with EN 806-4:2010, Test Method B or modified in accordance 
with information leaflet T 82-2011 "Leak Testing of Drinking Water Installations" 
of the German Central Association for Sanitary, Heating and Air Conditioning and
pressure and leak testing of other pipe systems and vessels.
●  hydrostatic pressure testing of drinking water installations with water in
accordance with EN 806-4:2010, Test Method C and for pressure and leak
testing of other pipe systems and vessels.
●  compressed air pump for controlled filling of all types of vessels with compressed 
air ≤ 0.8 MPa/8 bar/116 psi,
●  operation of compressed air tools up to an air requirements of ≤ 230 Nl/min
All other uses are not for the intended purpose and are therefore prohibited.
Attention: Use for the intended purpose also includes consideration and
observance of the national safety provisions, rules and regulations valid for
the application site, especially the following standards and rules of technology:
eng

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

115601Multi-push slw115600

Inhaltsverzeichnis