Mode 1-Blocked operation (1,0):
The operation for the heat pump is blocked for amaximum of two hours per day.
Mode 2-Normal operation (0,0):
The heat pump runs in energy-efficient normal mode.
Mode 3-Encouraged operation (0,1):
The operation of the heat pump is encouraged toincrease electricity
consumption for heating and warm water.
Mode 4-Ordered operation (1,1):
The heat pump is ordered to run, as long as this is possible, within the scope of
the control settings.
The controller has 2 control models:
i) The heat pump is switched on.
ii) The heat pump is switched on AND the warm water temperature is raised.
Configure SG ready power management settings
SgReadyFunction:
Disable/Enable sgready function.
RestartTime:
Interval between two launches of sgready.
SgReadyStartPower:
When the feed-in power exceeded the set value, the heat pump starts operation.
SgReadyStopPower:
When the feed-in power is less than the set value, the heat pump stops operation.
NOTE:
Zero-feed-in system, if the pv-generation achieves a predefined value
(Mode3). The heat pump will start automatically.