Bit
Function
5
AD
6
AMD
7
TG
Set point
Word 1
Bit
15
14
13
12
11
10
Fct
Unsigned integer 16 (bit)
If the product is in standard control mode, the output pressure is controlled so
that it remains between the pressure threshold and the maximum pressure value
(default [50 ... 10000 mbar].
If the parameter (2200:01) is not set to standard control mode, the set point
refers to the process data input.
11.5.2 Input data
Status
• Status word, word 0, unsigned integer 16 (bits)
Bit
15
14
13
12
11
10
Fct
E8
E7
E6
E5
E4
E3
Bit
Function
0
DI
4
AF
BR
5
AD
7
TG
Table 7: Product error list
Error
E1 [bit 08]
E2 [bit 09]
E3 [bit 10]
E4 [bit 11]
E5 [bit 12]
E6 [bit 13]
E7 [bit 14]
E8 [bit 15]
0
1
AVENTICS™ ED 07 / 12 Profinet | R414014550-BAL-001-AA | English
Meaning
Adaptation disabled
• For deactivating the adaptation
• Used if application mode parameter (0/1/2201)
= 101
AMD bit (Application mode disabled)
• Application mode is switched off (parameter
0/1/2201) AMD = 0, the type defined by the ap-
plication mode is executed
• 1 = the type defined by the application mode is
not executed.
• The product works in pressure control (corre-
sponds to 0/1/2201 = 0)
Bit for communication (switchover bit)
• Is output as an echo with input data TG.
• For checking the communication between
product and PLC
9
8
7
6
5
4
3
9
8
7
6
5
4
3
E2
E1 TG
AD
AF
/
BR
Meaning
Digital input
0 = input switched off
1 = input switched on
Adaption full filled
Used in application mode 101
1 = control adaptation completed
0 = control adaptation in progress
Brake active
Used in application mode 102
1 = brake active
0 = brake function not active
Set if AD has been activated in the control word
and parameter 0/1/2201 = 101 is set
Bit for communication (switchover bit)
Echo of TG bit from output data
Description
U
Electronics supply voltage U
L
range
U
Actuator supply voltage U
A
range
S1E Pressure sensor 1 error (working pres-
sure)
S2E Pressure sensor 2 error (output pressure)
P1L Working pressure too low
VE Valve error
CLA Coil current limitation active
PME Parameter and/or memory error
No error
Error
E1 ... E8: Product error (defined as Boolean). Each bit (E ... E) stands for an error or
a warning.
Controlled pressure (working pressure) p2 [mbar]
• Word 1
Bit
15
14
Fct
Unsigned integer 16 (bit)
Measured output pressure value [mbar].
Input pressure (supply pressure) p1 [mbar]
• Word 2
Bit
15
14
Fct
Unsigned integer 16 (bit)
Currently measured supply pressure: [0 ... 10000 mbar].
Analog process data input
• Word 3
Bit
15
14
2
1
0
Fct
Unsigned integer 16 (bit)
INFO: Scaling refers to parameter 2.
Control variable
• Word 4
Bit
15
14
Fct
Signed integer 16 (Bit)
Value range: [-100 ... 100]
11.6 Diagnostics
2
1
0
System diagnosis
DI
The implemented diagnostic module works separately from the application mod-
ule and checks the measurement data used.
Supply voltage diagnosis
The logic and valve operating voltage is monitored for undervoltage and over-
voltage. If the U
U
is set in the status word.
A
Diagnosis of the output and supply pressure sensor
The diagnostic module monitors the pressure sensor function.
If the sensor provides invalid data for a time period of t ≥ 200 ms, the following
error states are set:
• S1E in the status word: Pressure sensor p1 supply error
• S2E in the status word: Output pressure sensor p2 error
Coil current diagnosis
To avoid excessive heating, the actual current is monitored by the coil current
control.
The current is reduced and CLA set as the status word if the following applies:
• For a time period of t > 30 s, the actual coil current is higher than the value
wMaxCurrentCont[mA].
There is a pressure deviation greater than 50 mbar.
is outside the
L
11.6.1 Data recording
The product has an integrated scope function with a buffer of 500 values and a
is outside the
A
resolution of 1 ms for 6 recording channels. A maximum of 500 ms can be
recorded.
The recording is triggered by a trigger bit from the control word. The recording
finishes when the trigger bit is set to zero or 500 values have been written.
The measurement data is stored temporarily in the product's RAM.
The measuring channels are defined for the following as standard:
• General set point [mbar]
• Output pressure p2 [mbar]
• Regulator control variable U
• Actuator supply voltage U
13
12
11
10
9
8
7
13
12
11
10
9
8
7
13
12
11
10
9
8
7
13
12
11
10
9
8
7
or U
voltage are outside the defined range, the error flag U
L
A
k
[10 mV]
A
6
5
4
3
2
1
0
6
5
4
3
2
1
0
6
5
4
3
2
1
0
6
5
4
3
2
1
0
or
L
26