Recommended separation distances between portable and mobile RF telecommunications
equipment and the Gebrüder Martin SonicWeld Rx
®
The SonicWeld Rx
is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The user can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF telecommunications equipment (transmitters) and
the device as recommended below, depending on the maximum output power of the communications
equipment.
Rated maximum
output P of
transmitter in watts
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to
the transmitter manufacturer.
Note 1
Note 2
10

Disposal of the Device

Be sure to observe all national/local regulations and guidelines when disposing of the
packaging material and potentially infectious items (e.g. removed metal components).
In designing the device, we tried to avoid using composite materials wherever possible.
This allows a high degree of recycling. We therefore offer to take the device back for proper
disposal and recycling.
Be sure to observe your national/local rules and regulations governing disposal!
Marking of electric and electronic equipment in accordance with
Directive 2002/96/EC (WEEE Directive) and the German Electrical
and Electronic Equipment Act (ElektroG)
This symbol on the product or its packaging indicates that the product may not
be disposed of as normal household garbage.
74
Separation distance according to frequency of transmitter (in m)
150 kHz to 80 MHz
=
d
. 1
17
P
0.12
0.38
1.2
3.8
12
At 80 MHz and 800 MHz, the separation distance for the higher frequency
range applies.
These guidelines may not apply in all situations. Electromagnetic propagation
is affected by absorption and reflection from structures, objects and people.
Instructions for Use / Technical Description
Ultrasonic Unit SonicWeld Rx
®
80 MHz to 800 MHz
=
d
. 1
17
P
0.12
0.38
1.2
3.8
12
800 MHz to 2.5 GHz
=
d
. 2
33
P
0.23
0.73
2.3
7.3
23