1 | MI_2086: Arresting the Temperature sensor hot air eSTB after changing Heating assembly (E) or
distance for 201E is too large:
Bend the arbor closer to the heating element
The long side of the limit gauge has to touch the heating assembly / heat
a. If the distance is out of range bend the socket into the correct position by
using the arbor and check the distance again.
b. When the distance is OK reassemble the temperature Sensor eSTB into the
welded or screwed socket.
c. Check the distance for a last time, now between the assembled temperature
sensor eSTB and the heating element.
d. Reassemble the steam gas blower and all other components.
e. Don't forget to do a gas leak test for all affected gas components at last.
distance for 201E is too small:
distance is OK
Bend the arbor away from the
heating element
exchanger
Heat exchanger (G)