1 | MI_2086: Arresting the Temperature sensor hot air eSTB after changing Heating assembly (E) or
Heat exchanger (G)
RATIONAL-tool 1: 91.01.321
102 G, 201 G, 202 G
RATIONAL-tool 2:
91.01.346
61 G, 62 G, 101 G
101 E
62 E, 202 upper
heating assembly
102 E, 202 E
middle & lower
heating assembly
Check the distance by putting the limit gauge between the arbor and the
n
Heating assembly (E) or the heat exchanger (G) at the correct range. In gas
units you need to put in the limit gauge with an angle that measures the
shortest distance between the arbor and the heat exchanger.
arbor
limit gauge
Evaluation of the distance, e. g. for the electrical unit 201E:
n
12 / 104
61 E
201 E
7 mm
3 mm
5 mm
10 mm
Electrical unit (e.g. 61E)
arbor
shortest
distance
heating assembly
Min
10 mm
3 mm
8 mm
Min
18 mm
5 mm
10 mm
13 mm
limit gauge
heat
exchanger
pipe
Max
Limit Gauge
25 mm
6 mm
13 mm
Max
Limit Gauge
91.01.346
Gas unit (e.g. 62G)
arbor
shortest
distance
arbor
91.01.321