Connecting the Device
Battery connection steps for the installer
• Strip the 10mm
and clamp the connections with crimping pliers.
• Remove waterproof cover plate (2).
• Disassemble the waterproof connector plate
and pass the cable through it. (3).
• Connect the cable to the battery port marked "BAT"
of the inverter using a slotted screwdriver.
Be careful not to interchange the positive and
negative poles!
  WARNING!
Risk of electric shock due to damage!
Be careful not to apply too much torque
when connecting with the screwdriver
to avoid damage to the feed-through terminals
and a resulting risk of electric shock.
The limit load when connecting the Battery
terminals is 3 Nm.
Battery communication connection
• Pass the end of the battery communication cable
marked "PCS" through the waterproof cover plate
and connect it to the communication port of the
inverter marked "BMS".
• Connect the end of the communication cable
marked "BMS" to the RS485 interface of the battery.
• Assemble waterproof connectors
and waterproof covers plate (4).