Troubleshooting
Code Meaning
06
grid low vol
(grid low
voltage)
07
grid over vol
(grid over
voltage)
08
grid low freq
(grid low
frequency)
09
grid overFreq
(grid over
frequency)
10
Tripped
GFCI switch
(gfci over)
13
bus under vol
(bus under
voltage)
14
bus over vol
(bus over
voltage)
72
Description
The grid voltage
is abnormal.
The grid frequen-
cy is
abnormal.
The inverter GFCI
exceeds
standard.
The BUS voltage
is lower than
normal.
The BUS voltage
is over
maximum value.
Suggested solutions
• Make sure that the grid does not show
any abnormalities or eliminate them if
so.
• Restart the inverter and wait until it
functions normally.
• Check the PV string for direct or indi-
rect grounding phenomenons.
• Check the peripherals of the inverter
for current leakage.
• Check the input mode setting is cor-
rect.
• Restart the inverter and wait until it
functions normally.