Operation and Setting
PV input mode
By default, the PV input mode is set to independent (1).
Note: If, for example, parallel input is set to independent,
this will result in unbalanced PV output.
Other modes can be selected with the up/down keys
however, these are intended for testing purposes only and
not for setting by the customer.
1: Independent (Default setting for customers)
2: Parallel (function intended for test purposes)
3: Constant voltage (function intended for test purposes)
Confirm the selection with the enter key .
Anti Reverse / Zero feed-in
With anti-reverse enable, the grid feed-in of the inverter
is prevented.
By default, this is deactivated (disabled).
To change the current setting, select the desired
of the two options with the up/down keys
1: Disable Anti-Reverse
2: Enable Anti-Reverse
Confirm the selection with the enter key .
Application example:
If you do not want to feed electricity into the grid,
select "ENABLE" as described above.
48
/
;
/
:
--INPUT MODE--
1: INDEPENDANT
2: PARALLEL
3: CV
--Anti Reverse--
1: DISABLE
2: ENABLE