Herunterladen Diese Seite drucken

KKT KOLBE HKW10-1P3 Benutzerhandbuch Seite 155

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

System Setting
Use the up/down keys
to access from the following system parameters:
1: Work mode
2: EPS enable
3: Battery Wake-up
4: Remote control
5: Start time
6: PV Input
7: Anti Reverse (Zero feed-in)
To confirm your selection and enter the corresponding
settings menu, use the enter key .
To return to the first page of the user setting instead,
use the escape key .
Work mode
Use the up/down keys
work mode from the following:
1: Self consume (Default setting)
2: Peak shift
3: Battery priority
Confirm your selection with the enter key .
To return to the system setting options instead,
use the escape key .
 Note:
When commissioning the device or starting operation
after a long period of non-use,
first select the battery priority mode (BAT PRIORITY).
This is necessary to calibrate the SOC (battery charge level).
Otherwise, the battery will not be charged
and a fault message will appear.
/
to select the one you want
/
to select the desired
Operation and Setting
--SYS SETTING--
1: WORK MODE
2: EPS ENABLE
3: BAT WAKE-UP
4: REMOTE CTRL
5: START DELAY
6: PV INPUT
7: Anti Reverse
--WORK MODE--
1: SELF CONSUME
2: PEAK SHIFT
3: BAT PRIORITY