Battery information interface
BATTERY INFO
TYPE:
Lithium
TEMP:
26°C
SOC:
30%
Battery current interface
BMS PRMETER
CHAR VOL:
0.0V
CHARGE:
0A
DISCHA:
0A
Grid-connected
GRID
0.00Hz
U: 0.0V
0.0A
V: 0.0V
0.0A
W: 0.0V
0.0A
Inverter
INV:
0.00Hz
U: 0.0V
0.0A
V: 0.0V
0.0A
W: 0.0V
0.0A
Battery type (lead-acid, lithium battery)
Battery temperature
Percentage of battery capacity from the BMS
Battery BMS request:
Max. charging voltage
Max. charging current
Max. discharging current
Grid real-time frequency
Grid-phase U real-time voltage
Grid-phase V real-time voltage
Gird-phase W real-time voltage
CT: Current sensor accessories
Grid real-time frequency
INV-phase U:
real-time voltage
INV-phase V:
real-time voltage
INV-phase W: real-time voltage
Operation and Setting
CT real-time current
CT real-time current
CT real-time current
real-time current
real-time current
real-time current