Operation and Setting
Work time setting for peak shift mode
(2:PEAK SHIFT > WORKTIME)
When peak shift work mode is set, set the charging and
discharging time as follows.
It is possible to set three charging and discharging times
(TIME 1-3).
For this purpose, make sure that the time setting of the
inverter corresponds to the local time.
Use the enter key
time setting options.
Set the charging and discharging time
by using the up/down keys
of the following options :
Start of charging time 1 (CHAG START1)
End of charging time 1 (CHARGE END1)
Start of discharging time 1 (DISC START1)
End of discharging time 1 (DISCHA END1)
Use the enter key
ue with the up/down keys
by pressing the enter key .
To return to the work mode setting, use the escape key .
EPS Enable
To supply local consumers without power supply from the
public grid (by battery and PV), EPS must be activated
(default setting).
However, it can also be deactivated, e.g. for exclusive grid
feed-in / without battery use.
Use the up/down keys
of the two options:
1: Disable
2: Enable (Default setting)
Confirm the selection with the enter key .
46
to enter the corresponding
/
to select the desired one
to confirm the selection, set the time val-
/
and and confirm each input
/
to select the corresponding one
WORK MODE
1: SELF CONSUME
2: PEAK SHIFT
3: BAT PRIORITY
--WORKTIME--
1: TIME 1
2: TIME 2
3: TIME 3
CHAG START 1 00:00
CHARGE END 1 00:02
DISC START 1
00:03
DISCHA END 1 23:59
--EPS ENABLE--
1: DISABLE
2: ENABLE

Werbung