Parameter setting of the reactive mode
Use the up/down keys
the following options:
1: Power factor
2: Reactive power
3: QU wave (Settings reserved for this model)
4: QP wave (Settings reserved for this model)
Use the enter key
corresponding settings menu (1,2)
or
to activate the corresponding mode and return to the
operation setting options (3,4).
To cancel the operation and return to the operation setting
options, use the escape key .
Setting the selected parameters
After selecting the desired parameter, use the up/down
keys
/
to adjust the corresponding input value
and the enter key
the parameter setting of the reactive mode.
Power factor
The input value should be between L 0.80 and L 0.99
or C 0.8 and C 1.00.
Reactive power
The input value should be between -60% and +60%, which
varies according to the standard.
/
to select the desired one from
to confirm your selection and enter the
to confirm the selection and return to
Operation and Setting
--RUN SETTING--
1: REACT MODE
2: GRID POWER
3: DISC POWER
--REACT MODE--
4: PV POWER
1: POWER FACTOR
5: VAC-MIN
2: REACT POWER
6: VAC-MAX
3: QU WAVE
7: FAC-MIN
4: QP WAVE
8: FAC-MAX
9: ACTIVE
REF
--POWER FACTOR--
INPUT:
C1.00
--REACT POWER--
INPUT:
+00%