13.4.3 Example of setting output data

The following example illustrates the setting method for replacing the individual operations in the device with
transmission data (output data) from an external device.
Tab. 28
Operation
Perform gas check.
Perform slow wire feed.
Perform the welding process.
Stop operation.
The following operations can only be changed if changing settings by an external device is permitted.
Changing settings is permissible when offset 3/bit 7 is set to 1 and is not permissible when offset 3/bit 7
is set to 0.
Set the travel speed.
Set the welding procedure.
Set shielding gas type.
Set welding wire material.
Set the welding wire diameter. To set the welding wire diameter speed to "1.2",
Set the iArc mX Speed
penetration control.
Define voltage setting for
synergetic mode.
Set the welding current.
Set welding voltage to
individual setting.
Define setting for fine
adjustment of welding voltage
for synergetic mode.
Set the function.
EN - 66
Example of setting output data

Setting method

By setting offset 0/bit 3 to 1 gas rinsing is started.
By setting offset 0/bit 3 to 0 gas rinsing is ended.
By setting offset 0/bit 1 to 1 the wire feed is started.
By setting offset 0/bit 1 to 0 the wire feed is ended.
By setting offset 0/bit 0 to 1 the welding process is started.
By setting offset 0/bit 0 to 0 the welding process is ended.
By setting offset 0/bit 7 to 1 the operation is stopped.
By setting offset 0/bit 7 to 0 the operation stop is lifted.
To set the travel speed to "high", set offset 4/bit 0–1 to "1".
 Tab. 31 Setting the travel speed on page EN-70
To set the welding procedure to "DC", set offset 4/bit 2–4 to "1".
 Tab. 32 Setting the welding procedure on page EN-70
To set the shielding gas to "CO
 Tab. 33 Setting the shielding gas type on page EN-70
To set the welding wire material to "MILD STEEL",
set offset 5/bit 0–3 to "0".
Tab. 34 Setting the welding wire material on page EN-71
set offset 5/bit 4–6 to "3".
 Tab. 35 Setting the welding wire diameter on page EN-71
To activate the iArc mX Speed penetration control,
set offset 5/bit 7 to "1".
To activate the voltage setting for synergetic mode, set offset
8/bit 0 to "1".
To set the welding current to "350 A", set offset 9–10 to "350
(= 0 × 015E)".
(Offset 9: 0 × 5E, offset 10: 0 × 01)
To set the welding voltage to "32.0 V", set offset 13–14 to "320
(= 0 × 0140)".
(Offset 13: 0 × 40, offset 14: 0 × 01)
To set the fine adjustment of the welding voltage for synergetic
mode to "−10", set offset 15 to "−10 (= 0 × F6)".
To set F45 (special end crater filling sequence) to "ON", set
offset 18 to "45 (= 0.2D)"and set offset 19–20 to "1
(= 0 × 0001)".
(Offset 19: 0 × 01, offset 20: 0 × 00)
®
®
iROB
501, iROB
401, iROB
", set offset 4/bit 5–7 to "0".
2
®
301