iROB
501, iROB
401, iROB
Tab. 27
Offset
8
8
8
9–10
11–12
13–14
15
16–17
18/21/
24/27
19–20/
22–23/
25–26/
28–29
®
301
Simplified table for output data
Bit
Function
0
Voltage setting for
synergetic mode
1
Setting for wire
feed speed
2
Setting for wire
feed speed
–
Welding current
–
Wire feed speed
–
Welding voltage
–
Fine adjustment of
welding voltage for
synergetic mode
–
Wave frequency
–
Function
(port 1 to 4) no.
0–6
Function (port 1 to 4)
display change
–
Function (port 1 to 4)
setting value
13 IFR-800 fieldbus connection tool
Description
1: SYNERGETIC mode
0: individual mode
1: Setting for wire feed
0: Welding current setting
speed
1: valid
0: invalid
Specifies the welding current.
Specifies the wire feed speed.
Specifies the welding voltage.
Specifies the fine adjustment of welding voltage for
synergetic mode.
Specifies the wave frequency.
Sets the function number.
Changes the function value display.
Setting for function values.
EN - 65