iROB
501, iROB
401, iROB
Tab. 1
Pos. Name
Q
R
S
T
U
V
W
X
®
301
Control elements
<Arc dynamics> button
<Release start welding/end
crater parameter> button
<Penetration control> button
<Move-frequency> button
<Cooling unit on/off> button
<Synergy mode ON/OFF>
button
<Weld data capture> button
<Load> button
Function
Switches the arc characteristic from soft (+10) to hard (−10).
When the button is pressed, the LED illuminates and the
<Parameter setting> knob can be used to adjust the parameters.
The current characteristic is shown in the right digital display.
Enables the activation of start welding/end crater parameters
when the "two-step" operating mode is selected in automatic
mode (internal functions F45–47).
When the button is pressed, the LED illuminates and the
activation of start welding/end crater parameters is enabled.
Activates the iArc mX Speed penetration control.
The wire feed speed automatically adjusts so that the welding
current remains constant even if the free welding wire end
varies. This function is available when "steel", "steel filler wire",
"stainless steel" or "stainless steel filler wire" is selected.
LED on: Penetration control switched on.
LED off: Penetration control switched off.
Defines the double pulse frequency if iArc mX Move DC
welding procedure is selected.
When the button is pressed, the LED illuminates and the
<Parameter setting> knob can be used to adjust the frequency.
Switches the optional cooling unit on or off.
The unit is switched on/off when the button is pressed for
3 seconds.
LED on: Cooling unit is switched on.
LED off: Cooling unit is switched off.
Defines the welding voltage.
LED on:
Synergy mode ON: The welding voltage is automatically
adjusted according to the set welding current. Arc length
correction is carried out via the parameter setting.
LED off:
Synergy mode OFF: Power and voltage are set independent
of each other.
Switches weld data capture on or off.
LED on: Weld data capture is activated.
LED off: Weld data capture is deactivated.
Loads the welding parameters stored in the job memory.
 7.6 Managing the job memory on page EN-47