Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 101

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
Description for setting 2
Short-circuiting the terminals starts the wire feed.
Description for setting 3
If a wire feed is triggered after the terminals are short-circuited, the welding wire is retracted.
The terminals must be short-circuited before the wire feed signal is issued. To stop the operation, first switch
off the wire feed signal and then open the terminals.
Description for setting 4
Short-circuiting the terminals starts the welding process.
The starter terminal of the feed connection on the front of the machine is deactivated.
Description for setting 5
The parameters saved to the job memory can be read with a combination of signals.
The combination of the external terminals enables the reading of the welding parameters job no. 1 to 16
from the job memory of the welding power source. The corresponding job no. is listed in the table below.
Tab. 7
Job no.
Memory location
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
The external input terminal without setting 5 is considered as signal "OFF". These can be set by other
functions correspondent to the functions (external input terminal) that do not need the status "ON" for
the job no.
Example 1: Reading out the welding parameters from job no. 3
Set F30 to 5.
1
Set the signal of the external input terminals IN-EXT2 to ON.
2
Read out job no. 3.
3
Other functions can be used for F29, F31, and F32.
Example 2: Reading out the welding parameters from job no. 3
Set F29 and F32 to 5.
4
Set the signal of the external input terminals IN-EXT2 to OFF.
5
Read out job no. 3.
6
®
301
Input terminal function in the job
F29 (IN-EXT1)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
6 Putting into operation
Function (external input terminal)
F30 (IN-EXT2)
F31 (IN-EXT3)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
F32 (IN-EXT4)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
ON (closed)
EN - 21