Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 117

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
F14/F15: Adjusting the start control (time and current)
The welding parameters and the set welding current value determine the corresponding time and current for
the start control. If the correct amount of wire is not burned back during the start process, the current
and time must be adjusted accordingly. To increase the amount of wire burned back, the time and current
must be increased. To decrease the amount of wire burned back, the time and current must be decreased.
In the iArc mX Pulse DC welding procedure or iArc mX Move DC welding procedure the F14 value
is not displayed.
Adjustable range
Default value
Storage option
Description
Adjustable range
Default value
Storage option
Description
F16: Setting the wire creep
Wire creep refers to the slowing down of the welding wire feed speed to the wire feed speed at which the
welding wire is fed from the start of the process to the start of the arc. Wire creep is set automatically as
appropriate for the welding procedure and the welding wire diameter. This function enables the values to
be manually adjusted. If the arc does not ignite evenly, the wire feed speed must be reduced. If the arc ignites
evenly, the wire feed speed can be increased as much as possible to reduce the cycle time.
Adjustable range
Default value
Storage option
Description
F17/F18: Setting the backburn time/backburn voltage
By setting the backburn time (F17) and backburn voltage (F18) optimally, it is possible to prevent the
welding wire from adhering to the component at the end of the welding procedure. The shape of the free
welding wire end can be adjusted to optimize it for the next weld start.
The backburn time and backburn voltage are automatically set as appropriate for the welding procedure,
welding wire material, and welding wire diameter. This function allows for the fine adjustment of the values
if the welding wire nonetheless burns to ashes or burns back too far.
Adjustable range
Default value
Storage option
Description
Adjustable range
Default value
Storage option
Description
®
301
−50 to 50%
0%
No
Defines the control period of the starting current as welding starts.
−100 to 100 A
0 A
No
Defines control of the starting current as welding starts.
−1 to 1 m/min.
0 m/min.
Yes
Adjusts the wire creep.
−50 to 50 ms
0 ms
Yes
Sets the fine adjustment of the burning behavior at the welding wire end
during the backburn phase via the processing time.
−9.9 to +9.9 V
0 V
Yes
Sets the fine adjustment of the burning behavior at the welding wire end
during the backburn phase via the process voltage.
7 Operation
EN - 37

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Irob 401Irob 301

Inhaltsverzeichnis