Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 118

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 Operation
F19: Setting the switching off of the alarm
If an alarm is issued, the welding power source's current output can be interrupted. For some alarm codes,
it is possible to continue welding even if an alarm is detected. This can cause an alarm signal to be ignored.
This function can be used to force a stop.
When resetting alarms, the device behaves the same as when resetting faults.
 10.2 Faults on the control panel on page EN-55
Adjustable range
Default value
Storage option
Description
F20: Setting the lower threshold value of the mains voltage monitoring
Defines the threshold value from which a primary mains voltage is detected. If the mains voltage falls below
this value, an error message is issued. The specified mains voltage of the welding power source is between
340 V and 460 V. If the mains voltage falls below this value, it can have a profound negative impact on the
performance of the welding power source.
Adjustable range
Default value
Storage option
Description
F21: Activating the maximum capacity of the cooling fan
The speed of the fan motor and thus the cooling capacity is controlled depending on the temperature
measured in the power source. This Eco mode saves energy and prevents unnecessary foreign particles from
entering the device. This function allows the cooling fan to run at maximum speed during the entire
operation.
Adjustable range
Default value
Storage option
Description
F22: Deactivating the button tones
Deactivates the sounds when the user presses a button on the control panel.
Adjustable range
Default value
Storage option
Description
F23: Setting the time period until stand-by mode
If the device is not used for a longer period of time, it can be automatically switched to stand-by mode. Power
consumption is reduced. When in stand-by mode, a dot blinks in both digital displays. All other displays and
operations are switched OFF. Any operation terminates stand-by mode and the device returns to normal
mode.
Adjustable range
Default value
Storage option
Description
EN - 38
iROB
ON/OFF
OFF
No
ON: Every alarm stops the welding power source.
OFF: An alarm does not stop the welding power source.
260 V to 400 V
320 V
No
Defines the threshold value from which a fault is issued.
ON/OFF
OFF
No
OFF: Fan runs depending on the temperature measured in the power
source (Eco mode).
ON: The fan runs continuously at maximum power.
ON/OFF
ON
No
OFF: No sounds emitted.
ON: Sounds emitted.
0 to 10 min.
0 min.
No
Time after which the device is switched to standby mode.
0: Function deactivated.
®
®
®
501, iROB
401, iROB
301

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Irob 401Irob 301

Inhaltsverzeichnis