Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 153

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
Tab. 37
Offset
9–10
11–12
13–14
15
16–17
18
18
19–20
21
21
22–23
24
25–26
27
28–29
30–31
Tab. 38
Fault code
0
1–999
1001
1002
1003
1004
1101
1102
1103
1111
®
301
Details of input data
Bit
Function
Welding current
Wire feed speed
Welding voltage
Fine adjustment of
welding voltage for
synergetic mode
Wave frequency
0–6
Function (port 1) no.
7
Function (port 1)
display change
Function (port 1) setting
value
0–6
Function (port 2) no.
7
Function (port 2)
display change
Function (port 2) setting
value
7
Function (port 3)
display change
Function (port 3) setting
value
0–6
Function (port 4) no.
Function (port 4) setting
value
Fault code
Fault code
Description
No fault or "Acknowledge operation stop/fault" is in effect.
This value corresponds to the "E ***" fault codes.
 Tab. 19 Fault codes on the control panel and their remedy on page EN-55
Watchdog fault
Reception error from the fieldbus communication device to the control
component of the device.
Warning in case of reception error from the fieldbus communication device to the
control component of the device (the warning is issued if the reception error is
reset immediately after the error occurs).
Transmission error from the control component of the device to the fieldbus
communication device.
Welding mode warning. The specified welding mode does not exist.
Save location number warning. A save location number outside the valid range
was specified or an attempt is made to load a welding condition that was not
saved.
Warning for welding mode switch during welding. Issued if an impermissible
welding mode is indicated during welding. (The warning is automatically
canceled when the welding process is ended.)
Warning if weld start, wire feed, wire retract, gas discharge, or weld detection is
already set to ON and watchdog mode is activated or an error is reset. The
warning is reset when all elements are set to OFF.
13 IFR-800 fieldbus connection tool
Description
If the displayed measured value for offset 8/bit 7 has a
value of 0, the currently activated setting is defined.
If the displayed measured value for offset 8/bit 7 has a
value of 1, the measured value is set. Currently, fine
adjustment of the welding voltage for synergetic mode is
always set to 0.
The currently activated setting is defined.
The currently activated setting is defined.
If a fault occurs or a warning is issued, a fault code is
defined.
 Tab. 38 Fault code on page EN-73
EN - 73