Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 112

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 Operation
Setting the welding voltage
Switching to Synergy mode
The button's LED is on
The button's LED is off
EN - 32
A
V
m/min.
IE
I
V
Synergy
ON
Synergy mode is active
The welding voltage is automatically adjusted according to the set
welding current. Arc length correction is carried out via the parameter
setting. Independent adjustment is possible at any time via the
<Parameter setting> knob.
Synergy mode is inactive
The welding voltage can be set separately from the welding current
via the <Parameter setting> knob.
®
iROB
Press the <Parameter selection> button repeatedly until the
1
<Main welding parameter>, <Start welding parameter>,
or <End crater filling parameter> LED is selected.
±
Verify that the LED <V> (volts) is illuminated.
2
If not, press the <Toggle voltage> button.
3
±
Set the voltage with the <Parameter setting> knob.
4
The value is displayed in the right digital display.
In Synergy mode ON, voltage correction is executed based
on the value automatically assigned to the welding current.
In synergy mode OFF, the voltage can be set separate from
the welding current.
Press the <Synergy mode manual ON/OFF> button.
1
OFF
®
®
501, iROB
401, iROB
301

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Irob 401Irob 301

Inhaltsverzeichnis